Journal Basic Info
- Impact Factor: 1.809**
- H-Index: 6
- ISSN: 2474-1655
- DOI: 10.25107/2474-1655
Major Scope
- Forensic and Legal Medicine
- Cardiac Surgery
- Signs and Symptoms-Clinical Findings
- Asthma
- ENT
- Physiology
- Surgery Cases
- Pulmonary Medicine
Abstract
Citation: Ann Clin Case Rep. 2017;2(1):1369.DOI: 10.25107/2474-1655.1369
Intraductal Extracapsular Rupture of Silicone Breast Implant
Carl Seynnaeve and Wendie Berg
Department of Radiology, University of Pittsburgh Medical Center, USA
*Correspondance to: Carl Seynnaeve
PDF Full Text Case Report | Open Access
Abstract:
Complications of silicone implant rupture are commonly encountered, both clinically and by imaging. An unusual type of rupture with intraductal spread of silicone has only been described in a few case reports. The following is a case of intraductal spread of silicone illustrated by mammography, ultrasonography (US), and Magnetic Resonance (MR) imaging.
Keywords:
Cite the Article:
Seynnaeve C, Berg W. Intraductal Extracapsular Rupture of Silicone Breast Implant. Ann Clin Case Rep. 2017; 2: 1369.